INSTALLING DOWNDRAFT
(continued)
The lower support legs have
holes for mounting to the
cabinet floor and can be
installed on both sides
depending upon the length
required. Determine if the
holes should be in the front or
on the sides.
3) Carefully insert the unit into
the cutout. Due to the size and
weight, two people are
recommended when lifting
this unit. Make sure that the
downdraft is fully seated in the
cutout and the support arms
rest firmly on the countertop.
4) Adjust the lower support legs
until both rest firmly on the
cabinet floor. Place a level
vertically on the front side of
the blower box to make sure
that the unit is level and not leaning to
the front or rear. Once the unit is properly
aligned,mark a starter hole on the cabinet
floor where the lower support legs will
attach to the cabinet floor.
5) Remove the unit from the cabinet. Drill
starter holes in the cabinet floor for the
leg screws.
6) DCS downdrafts are shipped from the
factory ready to vent in the down
position. If you need to vent back, left or
right, then the blower must be reposi-
tioned.
To vent to the left or the right:
Four hex nuts attach the blower box to the
downdraft body. Remove all four nuts and
carefully remove the blower box. To vent left
or right, simply rotate the blower box 90° to
the left or right and re-assemble.
To vent to the rear:
Venting to the rear requires that the blower be
repositioned inside the blower box as
indicated in Fig. 09. The blower is attached to the blower box by 6 screws. Remove the blower from
the blower box. Note the position of the angle mounting rails on each side of the blower. To vent to
the rear, both mounting rails must be repositioned on the blower as illustrated in Fig. 10. Attach the
mounting rails as indicated. Re-attach the blower to the blower box. Re-attach the blower box to
end cap