DCS 6000
Installation Manual
Danish Interpretation Systems DIS
Digital Conference System
SW 6000 Conference Management
Software Version 5.3
Installation Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 51 52

Shrnutí obsahu

Strany 1 - DCS 6000

DCS 6000 Installation Manual Danish Interpretation Systems DIS Digital Conference System SW 6000 Conference Management Software Version 5.3 In

Strany 2

Danish Interpretation Systems Installation Manual Manual 01 19 60011 10l. At the command prompt, type Msdtc –install to install MSDTC. m. At the

Strany 3 - List of Contents

Danish Interpretation Systems Installation Manual Manual 01 19 60011 11 Computer Name Before you start installing the SW 6000 software package yo

Strany 4 - Introduction

Danish Interpretation Systems Installation Manual Manual 01 19 60011 12System design Prior to installing the software the system has to be designe

Strany 5

Danish Interpretation Systems Installation Manual Manual 01 19 60011 13 Installation design The CDA, CUI, CUA, CAA and ECA applications can all be

Strany 6

Danish Interpretation Systems Installation Manual Manual 01 19 60011 14Chairman control Design characteristics This design is used, where no tec

Strany 7

Danish Interpretation Systems Installation Manual Manual 01 19 60011 15 Installation with Multiple PCs Chairman & Technician control Design

Strany 8

Danish Interpretation Systems Installation Manual Manual 01 19 60011 16Chairman & Technician control including Display and External control De

Strany 9 - Windows 7 corrections

Danish Interpretation Systems Installation Manual Manual 01 19 60011 17 Chairman & Delegates control < 10 PCs Design characteristics This

Strany 10 - Manual 01 19 60011

Danish Interpretation Systems Installation Manual Manual 01 19 60011 18Chairman & Delegates control >10 PCs Design characteristics This de

Strany 11

Danish Interpretation Systems Installation Manual Manual 01 19 60011 19 Software Installation ‘One PC’ Installation The following installation pro

Strany 12 - System design

Danish Interpretation Systems Installation Manual Copyright © 2010 DIS SW 6000 Installation Manual ver 5.3 rev C 27/08/2010 No part of this pub

Strany 13 - Installation design

Danish Interpretation Systems Installation Manual Manual 01 19 60011 206 Click ‘Next’ 7 Accept the License Conditions and click ‘Next’

Strany 14 - Chairman control

Danish Interpretation Systems Installation Manual Manual 01 19 60011 21 8 The installation gives two choices: ‘One PC’ installation and ‘Advanced

Strany 15

Danish Interpretation Systems Installation Manual Manual 01 19 60011 2210 Click ‘Finish’ to complete the installation. Shortcuts to the applicati

Strany 16

Danish Interpretation Systems Installation Manual Manual 01 19 60011 23 ‘Advanced’ Installation The following installation procedure describes

Strany 17

Danish Interpretation Systems Installation Manual Manual 01 19 60011 24Installing SW 6000 After installing the ‘Prerequisites’, the installation w

Strany 18

Danish Interpretation Systems Installation Manual Manual 01 19 60011 25 8 The installation gives two choices: ‘One PC’ installation and ‘Advanced

Strany 19 - Software Installation

Danish Interpretation Systems Installation Manual Manual 01 19 60011 2610 Select ‘SW 6000-1’ as the database to be installed. INFO: The SW 6000 s

Strany 20

Danish Interpretation Systems Installation Manual Manual 01 19 60011 27 13 If you have selected ‘Create Hall definitions’ previously, the ‘Hall De

Strany 21

Danish Interpretation Systems Installation Manual Manual 01 19 60011 2817 Creation of the ‘Connection string’. Info: The ‘connection string’ is t

Strany 22

Danish Interpretation Systems Installation Manual Manual 01 19 60011 29 PC with: CUA and CAA Installing Prerequisites 1 Insert the CD with the ‘S

Strany 23

Danish Interpretation Systems Installation Manual Copyright © 2010 DIS SW 6000 Installation Manual ver 5.3 rev C 27/08/2010 No part of this pub

Strany 24 - Installing SW 6000

Danish Interpretation Systems Installation Manual Manual 01 19 60011 304 Accept the License Conditions and click ‘Next’ 5 The installation give

Strany 25

Danish Interpretation Systems Installation Manual Manual 01 19 60011 31 6 Select the ‘Conference Administrator Application Select the ‘Conferenc

Strany 26

Danish Interpretation Systems Installation Manual Manual 01 19 60011 32and ‘Default database name’ has to be filled in. 9 Create, Test and Save

Strany 27

Danish Interpretation Systems Installation Manual Manual 01 19 60011 33 If no license file is found, the license file is invalid or the license is

Strany 28

Danish Interpretation Systems Installation Manual Manual 01 19 60011 343 The driver has been installed and the CP 6001 Chip Card Programmer is no

Strany 29 - Installing Prerequisites

Danish Interpretation Systems Installation Manual Manual 01 19 60011 35 6 Click ‘Next’. 7 The driver has been installed and the CP 6001 Chip Ca

Strany 30

Danish Interpretation Systems Installation Manual Manual 01 19 60011 36Upgrading from previous versions Upgrading procedure (using old MSDE Databa

Strany 31

Danish Interpretation Systems Installation Manual Manual 01 19 60011 37 Upgrading procedure (using SQL 2008 Server Express) If you have a previou

Strany 32 - License file

Danish Interpretation Systems Installation Manual Manual 01 19 60011 387 The upgrade is now completed. Click ‘OK’ 8 Insert a new SW 6000 Licens

Strany 33

Danish Interpretation Systems Installation Manual Manual 01 19 60011 39 After installation of Software Customer logo The DIS logo in the CUA appl

Strany 34

Danish Interpretation Systems Installation Manual Manual 01 19 60011 4 Introduction This manual describes how to design a DCS 6000 Conference syst

Strany 35

Danish Interpretation Systems Installation Manual Manual 01 19 60011 40• CUI Computer Name: The name of the computer, where the CUI is installed

Strany 36

Danish Interpretation Systems Installation Manual Manual 01 19 60011 41 Advanced settings CUA, CDA Command line parameters for the CUA and CDA -CO

Strany 37

Danish Interpretation Systems Installation Manual Manual 01 19 60011 42Command line parameters for the ECA -W Show a communication window when th

Strany 38

Danish Interpretation Systems Installation Manual Manual 01 19 60011 43 5 Computer Setup The values in those fields are set during installation. T

Strany 39 - Customer logo

Danish Interpretation Systems Installation Manual Manual 01 19 60011 44-CONNECTSTRING "connectstring" Use this parameter to specify the

Strany 40

Danish Interpretation Systems Installation Manual Manual 01 19 60011 45 3 Using your account name and password, double-click the DefaultUserName e

Strany 41

Danish Interpretation Systems Installation Manual Manual 01 19 60011 46How to get started Pre-requisite steps before use The system has now been i

Strany 42 - Advanced settings CUI

Danish Interpretation Systems Installation Manual Manual 01 19 60011 47 8. Select the “Setup/Equipment/Conference Units” and assign a user type t

Strany 43

Danish Interpretation Systems Installation Manual Manual 01 19 60011 48 26. Select the delegate who is to be placed in Seat 2 and click >>.

Strany 44

Danish Interpretation Systems Installation Manual Manual 01 19 60011 49 1 To un-install select ‘SW6000’ in the list of programs and click ‘Remove

Strany 45

Danish Interpretation Systems Installation Manual Manual 01 19 60011 5 Preparations and Requirements Minimum requirement The minimum requirements

Strany 46

Danish Interpretation Systems Installation Manual Manual 01 19 60011 50Problems un-installing the SW 6000 Databases If the SW 6000 Applications ha

Strany 47

Danish Interpretation Systems Installation Manual Manual 01 19 60011 51 Descriptions of the more technical parts Database To use the SW 6000 appli

Strany 48

Danish Interpretation Systems Installation Manual Manual 01 19 60011 52The ‘Provider’ determines how the application should access the database. I

Strany 49 - Un-install SW 6000 Databases

Danish Interpretation Systems Installation Manual Manual 01 19 60011 6 Supported Operating Systems SW 6000 Software v5.3 support standard installa

Strany 50

Danish Interpretation Systems Installation Manual Manual 01 19 60011 7 Windows XP Professional Service Pack 2 (and 3) corrections Windows XP Profe

Strany 51 - Connect string

Danish Interpretation Systems Installation Manual Manual 01 19 60011 8 a. Click Start, and then click Run. b. In the Run dialog box, type Firewall

Strany 52

Danish Interpretation Systems Installation Manual Manual 01 19 60011 9 e. In the Local DTC Properties dialog box, click on Security tab. f. Click

Komentáře k této Příručce

Žádné komentáře